《Paper-Based Active Tactile Sensor Array》

  • 来源专题:绿色印刷—可穿戴电子
  • 编译者: 张宗鹏
  • 发布时间:2016-04-13
  • Abstract
    image

    A paper-based active tactile sensor ­array (PATSA) with a dynamic sensitivity of 0.35 V N−1 is demonstrated. The pixel position of the PATSA can be routed by analyzing the real-time recording voltages in the pressing process. The PATSA performance, which remains functional when removing partial areas, reveals that the device has a potential application to customized electronic skins.

  • 原文来源:;http://onlinelibrary.wiley.com/doi/10.1002/adma.201502470/abstract
相关报告
  • 《Parameter study of time-delay magnification in a biologically inspired, mechanically coupled acoustic sensor array》

    • 来源专题:水声领域信息监测
    • 发布时间:2016-11-25
    • Sound source localization uses interaural time difference(ITD) or interaural intensity difference cues, and most of the methods based on ITD are limited by the aperture of array. However, a kind of parasitoid fly called Ormia ochracea with coupled ears has a remarkable ability to localize calling of crickets regardless of the fly's small body size. The structure of fly's ear is generalized, and a multi-dimensional coupled system with an acoustic sensor array is proposed. The magnification factor of the phase difference in this system, which can be used to describe the ITD changes of signals from the coupled system, is chosen as the kernel parameter to measure the effect of coupling. The coupled system is optimized by choosing appropriate physical parameters such that the degree of magnification does not vary with angle of incidence. The simulation results demonstrate that the time delay between two signals increases by the coupled system, and the magnification factor remains stable as expected. Compared with the traditional general cross-correlation method, the localization error of the coupled system is reduced.
  • 《Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA》

    • 来源专题:中国科学院紫金山天文台科技信息监测服务
    • 编译者:zhoubz
    • 发布时间:2016-04-11
    • We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.