Evaluation of heating and chemical protocols for inactivating SARS-CoV-2
Boris Pastorino, Franck Touret, Magali Gilles, Xavier de Lamballerie, Remi N Charrel
doi: https://doi.org/10.1101/2020.04.11.036855
Abstract
Clinical samples collected in COVID-19 patients are commonly manipulated in BSL-2 laboratories for diagnostic purpose. We used the French norm NF-EN-14476+A2 derived from the European standard EN-14885. To avoid the risk of exposure of laboratory workers, we showed that Sodium-dodecyl-sulfate and Triton-X100 must be added to guanidinium thiocyanate-lysis buffers to obtain a 6-log reduction of infectious virus. Heating protocol consisting of 92C-15min was more effective rather than 56C-30min and 60C-60min to achieve 6-log reduction.
*注,本文为预印本论文手稿,是未经同行评审的初步报告,其观点仅供科研同行交流,并不是结论性内容,请使用者谨慎使用.