《Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena》

  • 来源专题:中国科学院紫金山天文台科技信息监测服务
  • 编译者: zhoubz
  • 发布时间:2016-04-11
  • The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum e?ciency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.

相关报告
  • 《Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA》

    • 来源专题:中国科学院紫金山天文台科技信息监测服务
    • 编译者:zhoubz
    • 发布时间:2016-04-11
    • We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
  • 《X-ray Performance of Back-Side Illuminated Type of Kyoto's X-ray Astronomical SOI Pixel Sensor, XRPIX.》

    • 来源专题:中国科学院紫金山天文台科技信息监测服务
    • 编译者:zhoubz
    • 发布时间:2016-04-11
    • We have been developing X-ray SOI pixel Sensors, called "XRPIX", for future X-ray astronomy satellites that enable us to observe in the wide energy band of 0.5-40 keV. Since XRPIXs have the circuitry layer with a thickness of about 8 {\mu}m in the front side of the sensor, it is impossible to detect low energy X-rays with a front-illuminated type. So, we have been developing back-illuminated type of XRPIX with a less 1 {\mu}m dead layer in the back-side, which enables the sensitivity to reach 0.5 keV. We produced two types of back-side illuminated (BI) XRPIXs, one of which is produced in "Pizza process" which LBNL developed and the other is processed in the ion implantation and laser annealing. We irradiated both of the BI-XRPIXs with soft X-ray and investigate soft X-ray performance of them. We report results from soft X-ray evaluation test of the device.